Cisco 350-601 (Implementing Cisco Data Center Core Technologies) certification exam is designed for professionals who wish to demonstrate their skills in implementing and managing complex data center solutions. 350-601 exam tests the candidate's knowledge of technologies and best practices involved in data center design, implementation, and operation. Successful completion of the exam leads to the award of the Cisco Certified Specialist - Data Center Core certification.


Cisco 350-601 certification exam is a professional-level exam that tests the knowledge and skills of IT professionals in implementing and managing data center technologies using Cisco products and solutions. 350-601 exam covers a range of topics related to data center technologies, including network design, storage networking, automation, security, and virtualization. Implementing Cisco Data Center Core Technologies (350-601 DCCOR) certification is recognized by employers around the world and can help IT professionals advance their careers in the field of data center technologies.

 

NEW QUESTION # 208
An engineer implements a Cisco UCS C-Series Server that must adhere to these security requirements:
Unencrypted communication must be disabled.
The session timeout must not exceed 15 minutes.
Unencrypted traffic must be automatically diverted.
CLI-based management must use nondefault ports.
Which configuration set meets these requirements?

  • A. Option C
  • B. Option D
  • C. Option B
  • D. Option A

Answer: C


NEW QUESTION # 209
An engineer configures the properties of a cisco UCS cisco integrated Management controller network adapter for a standalone cisco C-Series server. The Fallback Timeout in the vNIC was set to 600. When the failure occurs. The secondary must be used and then fallback when the primary interface becomes available again. Which action be taken to meet these requirements?

  • A. Enable Uplink failover.
  • B. Increase Cos to 6.
  • C. Disable VNTAG mode.
  • D. Set default VLAN on the adapters.

Answer: A

Explanation:
Enable Uplink Failover check box - Check this box if traffic on this vNIC should fail over to the secondary interface if there are communication problems. VNTAG mode is required for this option.
Failback timeout field - After a vNIC has started using its secondary interface, this setting controls how long the primary interface must be available before the system resumes using the primary interface for the vNIC. Enter a number of seconds between 0 and 600. VNTAG mode is required for this option.
https://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/gui/config/guide/1.5/b_Cisco_UCS_C-series_GUI_Configuration_Guide.151_chapter_01001.html


NEW QUESTION # 210
Which set of actions must be taken to backup service profiles, MAC pools, and VLANs and transfer the back up file to the external server using authentication?

  • A. Option C
  • B. Option B
  • C. Option D
  • D. Option A

Answer: C


NEW QUESTION # 211
An engineer must configure remote authentication on a Cisco UCS system. The user password must be encrypted before it is sent to the authentication server. The company security policy requires the server to be based on an open standard. Drag and drop the UCS CLI AAA configuration commands from the left into the order in which they must be implemented on the right. Not all commands are used.

Answer:

Explanation:

Explanation:
UCS-A# scope security
UCS-A /security # scope radius
UCS-A /security/radius # create server radiusserv7
UCS-A /security/radius/server* # set key
UCS-A /security/radius/server* # commit-buffer


NEW QUESTION # 212
Refer to the exhibit.

Two data center fabrics use VPC data center interconnect. The system MAC value on SW1 is
00:23:04:ee:be:20. Which value
must be set to configure the system MAC address?

  • A. 00:23:04:ee:be:14 on SW3
  • B. 46:43:32:e5:92:80 on SW2
  • C. 00:23:04:ee:be:20 on SW3
  • D. 00:23:04:ee:be:14 on SW2

Answer: C

Explanation:
In a vPC (Virtual Port Channel) data center interconnect, both vPC peer devices must have the same system MAC address to ensure that remote switches perceive them as a single logical switch. Since the system MAC value on SW1 is 00:23:04:ee:be:20, the same value must be configured on SW3 to maintain consistency in the vPC domain and ensure seamless communication between the two data center fabrics connected through this vPC interconnect.
References: = The explanation can be inferred from Cisco's official documentation and resources related to configuring and managing vPCs, ensuring that both peer devices in a vPC domain are configured with identical parameters, including the system MAC address.


NEW QUESTION # 213
Refer to the exhibit. A network engineer must use a Cisco on-box Python CLI to configure the BGP AS 65501 on Cisco Nexus 9000 Series Switch. The output from the command must be returned as raw output instead of JSON format. Which command set must be used to complete the configuration?

  • A. >>> clid("conf t")
    >>> clid("feature bgp")
    >>> clid("router bgp 65501")
  • B. >>> cli("conf t ; feature bgp ; router bgp 65501")
  • C. >>> clid("conf t ; feature bgp ; router bgp 65501")
  • D. >>> cli("conf t")
    >>> cli("feature bgp")
    >>> cli("router bgp 65501")

Answer: D

Explanation:
To run commands using the Cisco Nexus on-box Python CLI and receive raw (non-JSON) output, you must use the cli() function. The cli() method returns plain CLI output, while clid() returns structured JSON.
Thus:
* cli("...") is used for raw CLI output.
* Chaining commands in one string (like in options A and B) is not recommended and may fail
depending on syntax and prompt state.


NEW QUESTION # 214
An engineer has a primary fabric that is named UCS-A and a secondary fabric that is named UCS-B. A certificate request that has a subject name of sjc2016 for a keyring that is named kr2016 needs to be created.
The cluster IP address is 10.68.68.68. Which command set creates this certificate request?
A)

B)

C)

D)

  • A. Option D
  • B. Option C
  • C. Option B
  • D. Option A

Answer: B


NEW QUESTION # 215
Which two hypervisors does Cisco HyperFlex support? (Choose two.)

  • A. VMware vSphere
  • B. RedHat KVM
  • C. OpenStack
  • D. Microsoft Hyper-V
  • E. Citrix XenServer

Answer: A,D


NEW QUESTION # 216
Refer to the exhibit.

An engineer must monitor all LAN traffic on Fabric A from a blade server. Which source should be configured in the test-span monitor session to complete this task?

  • A. all uplink Ethernet ports
  • B. all uplink FCoE ports
  • C. all vNICs from the service profile that correspond to this server
  • D. all vHBAs from the service profile that correspond to this server

Answer: C

Explanation:
https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter45.html


NEW QUESTION # 217
Which two firmware packages are included in the Cisco UCS C-Series Rack-Mount UCS-Managed Server Software bundle? (Choose two.)

  • A. PSU
  • B. BIOS
  • C. system
  • D. third-party
  • E. CIMC

Answer: B,E

Explanation:
Options D and E are the correct firmware packages that are included in the Cisco UCS C-Series Rack-Mount UCS-Managed Server Software bundle. The bundle contains the firmware for the CIMC (Cisco Integrated Management Controller) and the BIOS (Basic Input/Output System) of the server. The other options are either not part of the bundle or not applicable for the server. References:
* Cisco UCS C-Series Rack-Mount Server Software and Firmware Compatibility Matrix for Cisco UCS Manager, Release 4.0 [Cisco UCS Manager], Cisco UCS C-Series Rack-Mount Server Software and Firmware Compatibility Matrix for Cisco UCS Manager, Release 4.0, Cisco UCS C-Series Rack-Mount UCS-Managed Server Software Bundle
* Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 4.0
[Cisco Integrated Management Controller], Cisco UCS C-Series Servers Integrated Management
* Controller CLI Configuration Guide, Release 4.0, Firmware Management


NEW QUESTION # 218

Refer to the exhibit. An engineer installs a new Cisco UCS B-Series server. The requirement is to install an operating system on a LUN that is provided by the Fibre Channel storage array. Which two steps must be configured in the boot policy to accomplish this goal? (Choose two ) Diss We Enforce vNIC/VHBA/iSCSI Name.

  • A. Configure a SAN Boot Target with a WWPN.
  • B. SCSI VNlCs and add Local LUN.
  • C. Add Local CD/DVD and SAN Boot.
  • D. Set Boot Order to External USB and LAN Boot Create .

Answer: B,C


NEW QUESTION # 219
Which statement describes monitoring Fibre Channel traffic on a Cisco UCS 6332 Fabric Interconnect?

  • A. Fibre Channel traffic is capable to be monitored as it is encapsulated as FCoE.
  • B. The destination port for monitoring must be an unassigned Fibre Channel port.
  • C. The monitoring of Fibre Channel traffic is limited to the default VSAN.
  • D. Fibre Channel traffic is monitored only on one vHBA per server.

Answer: A

Explanation:
Option D is the correct statement about monitoring Fibre Channel traffic on a Cisco UCS 6332 Fabric Interconnect. Fibre Channel traffic can be monitored even when it is encapsulated as FCoE (Fibre Channel over Ethernet) by using the SPAN (Switched Port Analyzer) feature. This allows network administrators to capture and analyze the Fibre Channel traffic flow and performance on any port or vHBA on the fabric interconnect. References:
* Cisco UCS Manager GUI Configuration Guide, Release 4.0 - Configuring Fibre Channel Traffic Monitoring [Cisco UCS Manager], Configuring Fibre Channel Traffic Monitoring, Configuring Fibre Channel Traffic Monitoring
* Cisco UCS Manager CLI Configuration Guide, Release 4.0 - Configuring Fibre Channel Traffic Monitoring [Cisco UCS Manager], Configuring Fibre Channel Traffic Monitoring, Configuring Fibre Channel Traffic Monitoring


NEW QUESTION # 220
An engineer is seeking the most optimal on demand CPU performance while configuring the BIOS settings of a UCS C-series rack mount server.
What setting will accomplish this goal?

  • A. C0/C1 state
  • B. C6 non-Retention
  • C. C6 Retention
  • D. C2 state

Answer: C

Explanation:
Section: Compute


NEW QUESTION # 221
Refer to the exhibit.

What is the result of this series of commands?

  • A. It verifies the firmware update on the server.
  • B. It activates the firmware on the next adapter boot.
  • C. It reboots the server immediately.
  • D. It updates the firmware on adapter 1/1/1 immediately.

Answer: B

Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/CLI-User-Guides/Firmware-Mgmt/4-0/b_UCSM_CLI_Firmware_Management_Guide_4-0/b_UCSM_CLI_Firmware_Management_Guide_4-0_chapter_011.html


NEW QUESTION # 222
A network engineer must configure FCoE on an interface of a Cisco MDS 9000 Series Switch. It should be used for mapping between VLAN 600 and VSAN 6. Drag and drop the commands from the bottom into their implementation order in the FCoE configuration. Not all commands are used.

Answer:

Explanation:

Explanation
Graphical user interface, text Description automatically generated


NEW QUESTION # 223
Which command reduces the amount of time it takes to complete the ISSU on a Cisco Nexus 7000 series switch that has dual supervisor modules and two I/O modules?

  • A. install all epld bootflash:<image>
  • B. install all kickstart <image>system<image>parallel
  • C. install all epld bootflash:<image>
  • D. install all kickstart<image>system<image>

Answer: B

Explanation:

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus7000/sw/upgrade/guide/ cisco_nexus7000_software_upgrade_and_downgrade_guide_8x.html
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/7_x/nx-os/upgrade/guide/ b_Cisco_Nexus_7000_Series_NX-OS_Software_Upgrade_and_Downgrade_Guide_Release_7- x.html#d54e307a1635


NEW QUESTION # 224
An engineer must configure Cisco IMC server management NIC for autonegotiation.
Which setting should be selected?

  • A. Cisco card
  • B. dedicated
  • C. shared LOM
  • D. shared LOM EXT

Answer: B

Explanation:
Section: Compute


NEW QUESTION # 225
Refer to the exhibit.

What is the outcome of this command when the ELPD is updated on a Cisco Nexus 9000 series switch?

  • A. shows a simulated upgrade of the EPLD
  • B. displays the impact of the upgrade on the operation of the switch
  • C. displays the compatibility of the EPLD upgrade and the image in the bootflash
  • D. upgrades the EPLD on the switch disruptively

Answer: C


NEW QUESTION # 226
A network engineer must implement RBAC on Cisco MDS 9000 Series Multilayer Switches.
Drag and drop the Cisco MDS 9000 Series roles from the left onto the correct categories on the right.

Answer:

Explanation:


NEW QUESTION # 227
Which two protocols are used by the NFSv4 protocol? (Choose two.)

  • A. Ethernet
  • B. UDP
  • C. FCP
  • D. TCP
  • E. IP

Answer: D,E


NEW QUESTION # 228
......

350-601 dumps Free Test Engine Verified By It Certified Experts: https://testprep.dumpsvalid.com/350-601-brain-dumps.html